Barium Carbonate SDS Safety Data Sheet of Supplier Exporter Manufacturers' Representative
Email: info@ammol.orgCall Toll Free +1-855-552-6665
Toll Free: 1-855-55-AMMOLBarium Carbonate
CAS Number: 513-77-9
Molecular Formula: BaCO3
Molecular Weight: 197.34
Barium CarbonateBarium Carbonate SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet 07-Feb-261. Product Identification
Product Name & Other Names: Barium Carbonate.
CAS No.: 513-77-9
EINECS: EC Number: 208-167-3
Molecular Weight: 197.34
Chemical Formula: BaCO3
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Supplier: American Molecules, 9910 Bent Oak Dr, Houston, TX 77040, USA.
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665.
In case of emergency contact: Will be given with the supply.2. Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Acute toxicity, Oral Category 4, (H302)
Labelling according to Regulation (EC) No 1272/2008
GHS Label Elements
IrritantSignal word: Warning
Hazard statement(s):
H302 Harmful if swallowed.Precautionary statement(s):
P261: Avoid breathing dust/ fume/ gas/ mist/ vapors/ spray.
P264: Wash … thoroughly after handling.
P270: Do not eat, drink, or smoke when using this product.
P271: Use only outdoors or in a well-ventilated area.
P280: Wear protective gloves/ eye protection/ face protection.
P304+340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P370+378: In case of fire: Use Water spray, Foam for extinction.
P301+312: IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell.
P403+233: Store in a well-ventilated place. Keep container tightly closed.
P501: Dispose of contents/container to an authorized agent only.3. Composition/Information on Ingredients
Product Name & Other Names: Barium Carbonate.
CAS No.: 513-77-9
EINECS: EC Number: 208-167-34. First Aid Measures
Always seek medical attention after first aid measures are provided.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact: Wipe off excess material from skin then immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact: Immediately flush eyes with plenty of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Get medical attention immediately.
Note to Physician: Symptomatic and supportive treatment is recommended.5. Fire Fighting Measures
Flammability of the Product: Non-flammable.
Products of Combustion: It emits oxides of barium and carbon when heated to decomposition.
Fire Extinguishing Media: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. Use means suitable for extinguishing surrounding fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. Fire-extinguishing work is done from the windward and a suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place. In case of fire in the surroundings, remove movable containers if safe to do so.6. Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Ventilate area of leak or spill. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment cleanup procedures and Storage: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g., sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container. Finish cleaning by spreading water on the contaminated surface and allow evacuation through the sanitary system if local laws permit.7. Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents and acids.8. Exposure Controls/Personal Protection
Airborne Exposure Limits: This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region-specific regulatory bodies.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full-face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.9. Physical and Chemical Properties
Appearance: White crystalline powder.
Odor: Odorless.
Odor threshold: Not applicable.
pH: Not available.
Relative density: about 4.29
Melting point/freezing point: 811C.
Initial boiling point and boiling range: 1450C. Decomposes.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility(ies): Practically insoluble in water.
Viscosity: Not available.
Molecular Weight: 197.34
Chemical Formula: BaCO310. Stability and Reactivity
Stability: It is stable under ordinary conditions of use and storage. It becomes unstable by heat.
Hazardous Decomposition Products: Oxides of barium and carbon.
Hazardous Polymerization: Will not occur.
Incompatibilities: Strong oxidizing agents. Heat.
Conditions to Avoid: Heat, Sunlight, Incompatibles.11. Toxicological Information
Toxicity to Animals:
LD50 Oral - Rat - 1.690 mg/kg.
Carcinogenic Effects: Not a reported carcinogen.
Mutagenic Effects: Not available.
Teratogenic Effects: Not available.
Developmental Toxicity: Not available.
Other Toxic Effects on Humans: Hazardous in case of ingestion, of inhalation.12. Ecological Information
Toxicity to animals:
Toxicity to fish static test LC50 - Danio rerio (zebra fish) - > 97,5 mg/l - 96 h.
Environmental Toxicity: Not available.
Persistence and degradability: No data available
Bioaccumulative potential: No data available.
Mobility in soil: No data available.13. Disposal Considerations
Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility. Processing use or contamination of this product may change the waste management options. State and local disposal regulations may differ from federal disposal regulations.
14. Transport Information
DOT USA & ADR/RID Europe: Not dangerous goods.
IMDG: Not dangerous goods.
IATA: Not dangerous goods.15. Regulatory Information
USA:
SARA 311/312 Hazards: Acute Health Hazard. See section 2.
California Prop. 65 Components: This product does not contain any chemicals known to the State of California to cause cancer, birth defects, or any other reproductive harm.16. Other Information
European Labeling in Accordance with EC Directives:
H302 Harmful if swallowed.Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************Please visit Main Page of Barium Carbonate Suppliers.
American Molecules, also known as ammol.org is a distributor, supplier and manufacturers' representative of all types of Pharmaceuticals, Functional Ingredients, Excipients and Specialty Chemicals in Texas USA. Our principals manufacture supply and export USP NF BP, Ph Eur, etc grades of chemicals pure and reagent grade, mineral fortifiers, FCC food grade. Tailor made particle size and customized specifications are offered. The principal's facility is having one or more of the certifications like FDA approval and GLP, cGMP, ISO9001, ISO14001, ISO/IEC 17025, ISO22000, FSSC 22000, ISO45001, FSSAI, Kosher, HALAL, COPP, WHO-GMP certified and Written Confirmation (WC) for export to Europe is available. The manufacturers suppliers and exporters observe WHO Good Manufacturing Practices and Good Laboratory Practices.
![]()
![]()
![]()
![]()
Suppliers and Manufacturers' Representative:
9910 Bent Oak Dr
Houston, TX 77040, USA
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665
Email: info@ammol.org
7 February, 2026