American Molecules - Ammol.org USA

Aluminium Glycinate or Dihydroxyaluminum Aminoacetate SDS Safety Data Sheet of Supplier Exporter Manufacturers' Representative

Call Toll Free +1-855-552-6665
Toll Free: 1-855-55-AMMOL

Aluminium Glycinate or Dihydroxyaluminum Aminoacetate
CAS Number: hydrate CAS 41354-48-7 and Anhydrous CAS 13682-92-3

Molecular Formula: C2H6AlNO4 Anhydrous
Molecular Weight: 135.06 Anhydrous

Aluminium Glycinate or Dihydroxyaluminum Aminoacetate Suppliers
Aluminium Glycinate or Dihydroxyaluminum Aminoacetate

Dihydroxyaluminum Aminoacetate SDS, Safety Data Sheet
MSDS Sheet, Material Safety Data Sheet
 04-Feb-24

1. Product Identification

Product Name & Other Names: Dihydroxyaluminum Aminoacetate or Dihydroxyaluminium Aminoacetate or Aluminum, (glycinato-N,O)dihydroxy.
CAS No.: 41354-48-7 or 13682-92-3
EINECS EC Code: 237-193-8
Molecular Weight: 135.06 (Anhydrous)
Chemical Formula: C2H6AlNO4xH2O
Relevant uses and uses advised against (if any): Industrial use.
Supplier: American Molecules, 9910 Bent Oak Dr, Houston, TX 77040, USA.
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665
In case of emergency contact: Will be given with the supply.

2. Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Hazard Class and Category Code(s), Regulation (EC) No 1272/2008 (CLP

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling Regulation as per GHS & EC 1272/2008 (CLP) & GHS

GHS Label Elements
NONE

Signal Words: None

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.

3. Composition/Information on Ingredients

Product Name & Other Names: Dihydroxyaluminum Aminoacetate or Dihydroxyaluminium Aminoacetate or Aluminum, (glycinato-N,O)dihydroxy.
CAS No.: 41354-48-7 or 13682-92-3
EINECS EC Code: 237-193-8

4. First Aid Measures

Always seek medical advice after the first aid treatment.

Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Contact medical center quickly. Never give anything by mouth to an unconscious person. Get medical attention.
Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes. Remove contaminated clothing and shoes. Get medical attention. Wash clothing before reuse. Thoroughly clean shoes before reuse.
Eye Contact: Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open. Cold water may be used. Get medical attention.

5. Fire Fighting Measures

Auto ignition temperature: NA
Combustible. High heat or direct flame is necessary to cause ignition. Toxic fumes and carbon monoxide and nitrogen oxides may be formed in fire.
Fire Extinguishing Media: Dry chemical, foam, or carbon dioxide. Do not use a solid stream of water since the stream will scatter and spread the fire. Water spray may be used to keep fire exposed containers cool.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode.

6. Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Ventilate area of leak or spill. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Large Spill: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.

7. Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.).
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents and acids. Storage and use areas should be No Smoking areas. Store in light resistant containers. Prevent any electrostatic discharge.

8. Exposure Controls/Personal Protection

Airborne Exposure Limits: Not available.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to the substance is apparent and engineering controls are not feasible, consult an industrial hygienist.
Skin Protection: Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact.
Eye Protection: Use chemical safety goggles and/or a full face shield where splashing is possible. Maintain eye wash fountain and quick-drench facilities in work area.

9. Physical and Chemical Properties

Appearance: Solid Crystals or Powder.
Odor: odorless.
Odor threshold: Not applicable.
pH: No data found.
Relative density: No data found.
Melting point/freezing point: No data found.
Initial boiling point and boiling range: No data found.
Flash point: No data found.
Auto-ignition temperature: No data found.
Decomposition temperature: No data found.
Upper/lower flammability or explosive limits: No data found.
Vapor pressure: No data found.
Vapor density: No data found.
Evaporation rate: No data found.
Flammability (solid, gas): No data found.
Partition coefficient: n-octanol/water: No data found.
Solubility: Insoluble in cold water
Viscosity: No data found.

10. Stability and Reactivity

Stability: It is stable under ordinary conditions of use and storage.
Hazardous Decomposition Products: Carbon dioxide, carbon monoxide, nitrogen oxides, aluminum oxide and toxic fumes may form when heated to decomposition.
Hazardous Polymerization: Not reported. However, it can explode under certain conditions.
Incompatibilities: Acids, oxidizing agents, heat, and sparks.
Conditions to Avoid: Heat, flames, ignition sources and incompatibles.

11. Toxicological Information

Oral rat LD50: No data found.
Oral mouse LD50 No data found.
Mutagenic effects: NA.
Teratogenicity: No data found.
Reproductive Effects: No data found.
Carcinogenicity: Not listed as a carcinogen.

12. Ecological Information

Toxicity Data: No data found.
The product and the products of its degradation are not known to be toxic.
Persistence and Degradability: No data found.
Mobility: No data found.
Bioaccumulation/ Accumulation: No data found.
Results of PBT and vPvB assessment: No data found.

13. Disposal Considerations

Whatever cannot be saved for recovery or recycling should be managed in an appropriate and approved waste disposal facility.

14. Transport Information

Land Transport DOT USA, TDG Canada & ADR/RID: Not Controlled.
Sea Transport IMO/IMDG: Not Controlled.
Air Transport ICAO/IATA: Not Controlled.

15. Regulatory Information

USA:
SARA 311/312 Hazards: See section 2.
California Prop. 65 Components: This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.

16. Other Information

DISCLAIMER: The information and recommendations set forth herein are presented in good faith and believed correct as of the date hereof. It is compiled from various sources, and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules, or insurance requirements applicable. This SDS MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a professionally trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose. This shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. In no case shall our company be liable to loss or damages by the product user.

Please visit Main Page of Aluminium Glycinate or Dihydroxyaluminum Aminoacetate Suppliers.

American Molecules, also known as ammol.org is a distributor, supplier and manufacturers' representative of all types of Pharmaceuticals, Functional Ingredients, Excipients and Specialty Chemicals in Texas USA. Our principals manufacture supply and export USP NF BP, Ph Eur, etc grades of chemicals pure and reagent grade, mineral fortifiers, FCC food grade. Tailor made particle size and customized specifications are offered. The principal's facility is having one or more of the certifications like FDA approval and GLP, cGMP, ISO9001, ISO14001, ISO/IEC 17025, ISO22000, FSSC 22000, ISO45001, FSSAI, Kosher, HALAL, COPP, WHO-GMP certified and Written Confirmation (WC) for export to Europe is available. The manufacturers suppliers and exporters observe WHO Good Manufacturing Practices and Good Laboratory Practices.

Pallet Drums Bottles Pail Container

Suppliers and Manufacturers' Representative:
American Molecules - Ammol.org USA
9910 Bent Oak Dr
Houston, TX 77040, USA
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665
Email: info@ammol.org