Section 1: Chemical Product and Identification

Product Name & Other Names: Iron Polymaltose Complex or Iron Poly Maltose Complex or Iron III Hydroxide Polymaltose Complex or Ferric Carboxymaltose.
CAS#: 53858-86-9
EINECS EC-No.: -
Relevant uses and uses advised against (if any): Laboratory and Industrial Manufacturing.
Supplier: American Molecules, 9910 Bent Oak Dr, Houston, TX 77040, USA.
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665.
In case of emergency contact: Will be given with the supply.

Section 2: Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling according to GHS & Regulation (EC) No 1272/2008

GHS Label Elements
NONE

Signal Word: None

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P302+P352: IF ON SKIN: Wash with plenty of soap and water.
P303+P361+P353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304+P340: IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.

Section 3: Composition and Information on Ingredients

Product Name & Other Names: Iron Polymaltose Complex or Iron Poly Maltose Complex or Iron III Hydroxide Polymaltose Complex or Ferric Carboxymaltose.
CAS#: 53858-86-9

Section 4: First Aid Measures

Always seek medical attention after first aid measures are provided.

Eye Contact: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention.
Skin Contact: In case of contact, immediately flush skin with plenty of water. Cover the irritated skin with an emollient. Thoroughly clean shoes and clothes before reuse. Get medical attention.
Inhalation: If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
Ingestion: Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately.

Section 5: Fire and Explosion Data

Flammability of the Product: Not flammable. Will burn at higher temperature.
Products of Combustion: Some metallic oxides, carbon oxides and fumes.
Explosion Hazards in Presence of Various Substances: Slightly explosive in presence of open flames and sparks. Fine dust dispersed in air in sufficient concentrations, and in the presence of an ignition source is a potential dust explosion hazard.
Fire Fighting Media and Instructions: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes.

Section 6: Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.).
Environmental precautions: Do not let the product enter drains, soil or water sources.
Methods and materials used for containment Cleanup procedures and Storage: Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminatedsurface and dispose as per law.

Section 7: Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.).
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents.

Section 8: Exposure Controls/Personal Protection

Exposure Limits: Not established.
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Handle in accordance with good industrial hygiene and safety practice.

Section 9: Physical and Chemical Properties

Physical state and appearance: Brown, amorphous powder.
Odor: No data found.
Odor threshold: No data found.
pH (2%w/v Iron Solution): 5 to 7
Relative density: No data found.
Melting Point: No data found.
Initial boiling point and boiling range: No data found.
Flash point: No data found.
Auto-ignition temperature: No data found.
Decomposition temperature: No data found.
Upper/lower flammability or explosive limits: No data found.
Vapor pressure: No data found.
Vapor density: No data found.
Evaporation rate: No data found.
Flammability (solid, gas): No data found.
Partition coefficient: n-octanol/water: No data found.
Solubility(ies): No data found.
Viscosity: No data found.

Section 10: Stability and Reactivity Data

Stability: It is stable.
Incompatible materials: Strong oxidizing agents
Incompatibility with various substances: Contact with incompatible materials. Heat, sparks, flames. Avoid dust formation.
Polymerization: Will not occur.
Hazardous Decomposition Products: Metallic oxides, carbon oxides and fumes.

Section 11: Toxicological Information

Toxicity to Animals: No data found.
Carcinogenicity: No component of this product present at levels greater than or equal to 0.1% is identified as probable or confirmed human carcinogen by IARC, ACGIH, OSHA and NTP.
Mutagenic Effects: No data found.
Teratogenic Effects: No data found.
Environmental Toxicity: No data found.

Section 12: Ecological Information

Ecotoxicity: No data found.
Persistence and Degradability: Soluble in water Persistence is unlikely based on information available.
Mobility: Will likely be mobile in the environment due to its water solubility.
Results of PBT and vPvB assessment: Not PBT or vPvB.

Section 13: Disposal Considerations

Waste Disposal: Waste must be disposed of in accordance legal regulations.

Section 14: Transport Information

DOT USA, TDG Canada & ADR/RID Europe: Not controlled
IMO/IMDG: Not controlled
IATA: Not controlled.

Section 15: Other Regulatory Information

USA:
SARA 311/312 Hazard Categories: See section 2
California Proposition 65: Not listed.

Section 16 - Additional Information

Disclaimer:
**************************
Our company provides this MSDS sheet in good faith but makes no representation as to its comprehensiveness or accuracy. This SDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a properly trained person using this product. The above information has been compiled from various sources and has the possibility of discrepancy and being out-dated information. Individuals receiving the information must exercise their independent judgment and do further search in determining its appropriateness for a particular purpose. In no case shall our company be liable to loss or damages by the product user.
**************************

Please visit Main Page of Iron Polymaltose or Ferric Carboxymaltose Suppliers.

American Molecules, also known as ammol.org is a distributor, supplier and manufacturers' representative of all types of Pharmaceuticals, Functional Ingredients, Excipients and Specialty Chemicals in Texas USA. Our principals manufacture supply and export USP NF BP, Ph Eur, etc grades of chemicals pure and reagent grade, mineral fortifiers, FCC food grade. Tailor made particle size and customized specifications are offered. The principal's facility is having one or more of the certifications like FDA approval and GLP, cGMP, ISO9001, ISO14001, ISO/IEC 17025, ISO22000, FSSC 22000, ISO45001, FSSAI, Kosher, HALAL, COPP, WHO-GMP certified and Written Confirmation (WC) for export to Europe is available. The manufacturers suppliers and exporters observe WHO Good Manufacturing Practices and Good Laboratory Practices.

Pallet Drums Bottles Pail Container

Suppliers and Manufacturers' Representative:
American Molecules - Ammol.org USA
9910 Bent Oak Dr
Houston, TX 77040, USA
Call Toll Free: 1-855-55-AMMOL 1-855-552-6665
Email: info@ammol.org

22 August, 2026