Corn Syrup Solids and Corn Syrup  |  Dextrin   |  Dextrose   |   D-Mannose or Mannose  |  D-Ribose  |  D-Xylose  |  D-Galactose Suppliers  |  High Fructose Corn Syrup HFCS  |  Lactose   |  Maltobionic Acid   |  Maltodextrin   | Monosodium Glutamate   |   Sodium Alginate   |  Sodium Ascorbate   |  Sodium Benzoate   |   Sodium Starch Glycolate   |  Corn Starch or Maize Starch   |   Sucrose Low Endotoxin   |  Sucrose Monolaurate or Sucrose Laurate   |  Sucrose Monostearate or Sucrose Stearate   |  and more --

D-Galactose or Galactose or D-Galactopyranose
CAS Number: 3646-73-9 or 59-23-4

Molecular Formula: C6H12O6
Molecular Weight: 180.16

D-Galactose or Galactose or D-Galactopyranose Suppliers
D-Galactose or Galactose or D-Galactopyranose

Specifications of Galactose USP NF Grade:
C6H12O6 --- 180.16
α-d-Galactopyranose --- CAS 3646-73-9

DEFINITION
Galactose is one of the products of the metabolism of lactose, a naturally occurring sugar in dairy products, by the digestive enzyme lactase.

IDENTIFICATION
A. 
Infrared Absorption
B. Thin-Layer Chromatographic Identification Test
To pass the test.
Acceptance criteria: The RF of the principal spot of the Sample solution corresponds to that of Standard solution A.

Residue on Ignition: NMT 0.1%
Limit of Lead:
To pass the test.
Acceptance criteria: NMT 0.5 micro-g/g
Barium:
Standard solution: Add 6 mL of water to 5 mL of the Sample solution prepared for the Acidity test.
Sample solution: Add 5 mL of water and 1 mL of dilute sulfuric acid to 5 mL of the Sample solution prepared for the Acidity test. Allow to stand for 1 h.
Acceptance criteria: Any opalescence in the Sample solution is not more intense than that in the Standard solution.
Appearance of Solution:
To pass the test.
Acceptance criteria: The Sample solution is not more intensely colored than the Control solution.
Microbial Enumeration Tests and Tests for Specified Microorganisms: The total aerobic microbial count does not exceed 103 cfu/g, and the total combined molds and yeasts count does not exceed 102 cfu/g. It meets the requirements of the test for absence of Salmonella species, Escherichia coli, Staphylcoccus aureus, and Pseudomonas aeruginosa.
Optical Rotation, Specific Rotation:
To pass the test.
Acceptance criteria: +78.0° to +81.5°
Acidity:
Sample solution: Dissolve 10.0 g of Galactose, with heating at 50C, in 40 mL of carbon dioxide-free water. Dilute with carbon dioxide-free water to 50 mL. [Note— Use this solution for the Barium test.]
Analysis: To 30 mL of the Sample solution add 0.3 mL of phenolphthalein and titrate with 0.01 N sodium hydroxide to a pink color.
Acceptance criteria: NMT 1.5 mL of 0.01 N sodium hydroxide is required.
Water Determination: NMT 1.0%

We also supply D-Galactose or Galactose or D-Galactopyranose of BP Ph Eur grade.

Please visit SDS Safety Data Sheet of D-Galactose or Galactose or D-Galactopyranose Suppliers.

American Molecules, also known as ammol.org is a distributor, supplier and manufacturers' representative of all types of Pharmaceuticals, Functional Ingredients, Excipients and Specialty Chemicals in Texas USA. Our principals manufacture supply and export USP NF BP, Ph Eur, etc grades of chemicals pure and reagent grade, mineral fortifiers, FCC food grade. Tailor made particle size and customized specifications are offered. The principal's facility is having one or more of the certifications like FDA approval and GLP, cGMP, ISO9001, ISO14001, ISO/IEC 17025, ISO22000, FSSC 22000, ISO45001, FSSAI, Kosher, HALAL, COPP, WHO-GMP certified and Written Confirmation (WC) for export to Europe is available. The manufacturers suppliers and exporters observe WHO Good Manufacturing Practices and Good Laboratory Practices.